Fire Hydrant Systems

Complete design, installation, and maintenance of fire hydrant systems per NFPA 14 & NFPA 20

Fire hydrant system

System Components

  • Fire Pumps: Electric motor driven and diesel engine driven pumps ranging from 250 GPM to 2500 GPM capacity
  • Jockey Pumps: Pressure maintenance pumps to keep system pressurized
  • Water Storage: Underground and overhead tanks with adequate capacity as per NBC requirements
  • Hydrant Valves: Single and double headed landing valves with instantaneous couplings
  • Hose Reels: First aid hose reels for immediate fire response
  • Control Panels: Automatic pump controllers with pressure switches and monitoring
  • Piping Network: MS/GI pipes with proper sizing based on hydraulic calculations

Our Services

  • Site survey and fire risk assessment
  • Hydraulic design and calculations
  • Equipment selection and procurement
  • Complete installation and piping work
  • Pressure testing and commissioning
  • Fire department approval assistance
  • Annual maintenance contracts (AMC)
  • Pump performance testing

Fire Sprinkler Systems

Automatic sprinkler systems designed per NFPA 13 for optimal fire protection

Fire sprinkler system

Types of Sprinkler Systems

  • Wet Pipe Systems: Most common system with water-filled pipes, suitable for heated buildings
  • Dry Pipe Systems: Air or nitrogen filled pipes for unheated areas and freezing conditions
  • Pre-Action Systems: Double interlock systems for data centers and sensitive areas
  • Deluge Systems: Open sprinklers for high-hazard areas with flammable materials
  • ESFR Systems: Early Suppression Fast Response for high-rack storage warehouses

Installation Services

  • NFPA 13 compliant design drawings
  • Hydraulic calculations and reports
  • Complete installation with certified fitters
  • Hydrostatic pressure testing
  • System flushing and commissioning
  • Authority approvals and NOC
  • Quarterly and annual inspections

VRV/VRF AC Systems

Variable Refrigerant Volume and Variable Refrigerant Flow air conditioning systems

VRV VRF AC system

System Features

  • Energy Efficiency: Up to 40% energy savings compared to conventional AC systems
  • Individual Control: Independent temperature control for each indoor unit
  • Flexible Design: One outdoor unit can connect to multiple indoor units
  • Quiet Operation: Low noise levels suitable for offices and residential spaces
  • Space Saving: Compact design with minimal space requirements

Our VRV/VRF Services

  • Load calculation and system design
  • Equipment selection and procurement
  • Complete installation with refrigerant piping
  • Electrical wiring and controls
  • Commissioning and testing
  • Annual maintenance contracts
  • Energy audit and optimization

Chiller Installation & Maintenance

Water-cooled and air-cooled chiller systems for large commercial buildings

Chiller system

Chiller Types

  • Water-Cooled Chillers: High efficiency for large capacity requirements with cooling tower
  • Air-Cooled Chillers: Compact design without cooling tower, suitable for medium capacity
  • Screw Chillers: Reliable and efficient for industrial applications
  • Centrifugal Chillers: High capacity for large commercial buildings

Chiller Services

  • Cooling load calculations
  • Chiller selection and sizing
  • Complete installation with piping
  • Cooling tower and pump installation
  • Control panel and automation
  • Preventive maintenance programs
  • Chiller tube cleaning and servicing
  • Refrigerant leak detection and repair

Fire Alarm Systems

Intelligent fire detection and alarm systems per NFPA 72

Fire alarm system

System Types

  • Addressable Systems: Intelligent systems with individual device identification and location
  • Conventional Systems: Zone-based systems for smaller buildings
  • Wireless Systems: Radio frequency systems for heritage buildings
  • Aspirating Systems: VESDA systems for ultra-early smoke detection

Our Alarm Services

  • Fire risk assessment and system design
  • NFPA 72 compliant installation
  • Programming and commissioning
  • Sensitivity testing and calibration
  • Monthly, quarterly, and annual testing
  • False alarm investigation
  • System upgrades and expansions

Clean Agent Suppression Systems

Clean agent fire suppression per NFPA 2001 for sensitive equipment protection

Clean agent suppression system

Suppression Agents

  • FM-200 (HFC-227ea): Fast-acting clean agent, safe for occupied spaces
  • Novec 1230: Environmentally friendly agent with zero ozone depletion
  • CO2 Systems: Carbon dioxide for total flooding and local application
  • Inert Gas (IG-541): Nitrogen, argon, and CO2 mixture for deep-seated fires

Installation & Maintenance

  • NFPA 2001 compliant design
  • Room integrity testing
  • Complete installation and commissioning
  • Discharge testing (with agent or nitrogen)
  • Annual cylinder weighing and inspection
  • Detection system testing
  • Agent refilling services

Ductable AC Systems

Concealed ductable air conditioning for uniform cooling distribution

Ductable AC system

System Benefits

  • Concealed Design: Indoor unit hidden in false ceiling for aesthetic appeal
  • Uniform Cooling: Even temperature distribution through ducting
  • Multiple Zones: Cooling for multiple rooms from single unit
  • Fresh Air Integration: Option to introduce fresh air ventilation
  • Quiet Operation: Minimal noise in occupied spaces

Installation Services

  • Room-by-room load calculation
  • Duct design and layout
  • Equipment supply and installation
  • Ductwork fabrication and installation
  • Diffuser and grille installation
  • Testing and commissioning
  • Regular maintenance and filter cleaning

Building Management System (BMS)

Intelligent building automation for HVAC control and energy management

BMS system

BMS Features

  • HVAC Control: Centralized control of chillers, AHUs, FCUs, and VRV systems
  • Energy Management: Real-time monitoring and optimization of energy consumption
  • Fire Alarm Integration: Integration with fire detection and suppression systems
  • Lighting Control: Automated lighting based on occupancy and daylight
  • Remote Monitoring: Web-based and mobile app access

BMS Services

  • System design and architecture
  • Hardware and software supply
  • Sensor and controller installation
  • Programming and configuration
  • Graphics and user interface development
  • Training and documentation
  • Annual maintenance and support
  • System upgrades and expansions

Need Fire Fighting or HVAC Services?

Get customized solutions from certified engineers

Request Consultation